LDR | | 02756nmm uu200469 4500 |
001 | | 000000333372 |
005 | | 20240805172914 |
008 | | 181129s2018 |||||||||||||||||c||eng d |
020 | |
▼a 9780438027060 |
035 | |
▼a (MiAaPQ)AAI10816736 |
035 | |
▼a (MiAaPQ)cornellgrad:10843 |
040 | |
▼a MiAaPQ
▼c MiAaPQ
▼d 248032 |
082 | 0 |
▼a 333 |
100 | 1 |
▼a Aguirre, Gloria Andrea. |
245 | 10 |
▼a Geothermal Heat Pump Systems Modeling: Technical, Economic, and Environmental Analysis for Nationwide Deployment in Cooling-Dominated Applications and for Sustainable Neighborhood Design. |
260 | |
▼a [S.l.] :
▼b Cornell University.,
▼c 2018 |
260 | 1 |
▼a Ann Arbor :
▼b ProQuest Dissertations & Theses,
▼c 2018 |
300 | |
▼a 406 p. |
500 | |
▼a Source: Dissertation Abstracts International, Volume: 79-10(E), Section: B. |
500 | |
▼a Adviser: Jefferson W. Tester. |
502 | 1 |
▼a Thesis (Ph.D.)--Cornell University, 2018. |
520 | |
▼a Multidisciplinary frameworks and tools are developed to assess the performance of geothermal heat pump (GHP) systems for heating and cooling applications in residential and commercial buildings. The technical, economic, and environmental perform |
520 | |
▼a Tens of thousands of cellular towers are in operation across the U.S. often accompanied by small shelters that house electrical equipment continuously generating around 8 kWth of heat. The annual electricity consumption and corresponding carbon |
520 | |
▼a With no consideration of incentives or rebates, base case results show that the total cost of ownership (TCO) for all cooling configurations is the lowest for states located in cooler climates (e.g., Maine, Minnesota, and Colorado), and the high |
520 | |
▼a Rust Belt cities in the U.S. have experienced years of severe economic and population decline, but possess many legacies and assets that present opportunities for sustainable revitalization and economic growth. Several frameworks and tools are p |
520 | |
▼a In Utica, GSDE networks are economically feasible for systems designed to cover a portion of the annual peak heating load of the area, with the remainder load covered by a supplemental natural gas peak boiler. The capital costs and payback perio |
590 | |
▼a School code: 0058. |
650 | 4 |
▼a Alternative Energy. |
650 | 4 |
▼a Geological engineering. |
650 | 4 |
▼a Systems science. |
690 | |
▼a 0363 |
690 | |
▼a 0466 |
690 | |
▼a 0790 |
710 | 20 |
▼a Cornell University.
▼b Geological Sciences. |
773 | 0 |
▼t Dissertation Abstracts International
▼g 79-10B(E). |
773 | |
▼t Dissertation Abstract International |
790 | |
▼a 0058 |
791 | |
▼a Ph.D. |
792 | |
▼a 2018 |
793 | |
▼a English |
856 | 40 |
▼u http://www.riss.kr/pdu/ddodLink.do?id=T14998284
▼n KERIS |
980 | |
▼a 201812
▼f 2019 |
990 | |
▼a 관리자 |